VTOM5X(n)
형식표시방법

1. Basic Model
| Symbol | Description |
| VTOM5 | Minimultiple, VTOM5 |
2. Basic Model
| Symbol | Description |
| 4 | VTOM5, 4-stacked pump |
| 5 | VTOM5, 5-stacked pump |
| 6 | VTOM5, 6-stacked pump |
| 7 | VTOM5, 7-stacked pump |
| 8 | VTOM5, 8-stacked pump |
| 9 | VTOM5, 9-stacked pump |
| 10 | VTOM5, 10-stacked pump |
| 11 | VTOM5, 11-stacked pump |
| 12 | VTOM5, 12-stacked pump |
| 13 | VTOM5, 13-stacked pump |
| 14 | VTOM5, 14-stacked pump |
| 15 | VTOM5, 15-stacked pump |
| 16 | VTOM5, 16-stacked pump |
3. Air Control Valve
| Symbol | Description |
| Blank | No air control valve |
| A1 | Air control valve, AC 110V |
| A2 | Air control valve, AC 220V |
| A3 | Air control valve, DC 24V |
4. Vacuum Release Control Valve
| Symbol | Description |
| Blank | No vacuum release control valve |
| R1 | Vacuum release control valve, AC 110V |
| R2 | Vacuum release control valve, AC 220V |
| R3 | Vacuum release control valve, DC 24V |
5. Valve Terminal
| Symbol | Description |
| Blank | No air control valve ☛ “Option 2”, Air control valve |
| DN | Solenoid terminal, DIN type, No lead wire |
| DL | Solenoid terminal, DIN type, No lead wire, Lamp |
| CL | Solenoid terminal, Connector type, 30 cm lead wire |
| ☛ “The valve terminal ” option is only available when you chose air control valve. | |
| ☛ “CL” option is only available with DC24V. | |
| 2B | Solenoid terminal, DIN, 2-in-1 BUS cable |
6. Sealing Material
| Symbol | Description |
| Blank | NBR sealing material |
| V | Viton sealing material |
| E | EPDM sealing material |
기술정보
1. General Specifications
| Max Vacuum Level | -85 kPa |
| Open Vacuum Flow | 27 Nl/min |
| Feed Pressure | 5.5 bar (Max 7 bar) |
| Air Consumption | 21 Nl/min |
| Temperature | -20 ~ 80 ℃ |
| Weight – 2-stacked pump | 360 g (Increased 35 g per additional stack) |
2. Vacuum Flow
| Max Vacuum | Feed Pressure | Vacuum Flow (Nl/min) at different vacuum level (-kPa) | |||||||||
| -kPa | bar | 0 | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 |
| 85 | 5.5 | 27 | 16 | 13 | 12 | 11 | 8 | 6 | 2.4 | 0.66 | – |
3. Evacuation Time
| Feed Pressure | Air Consumption | Evacuation time in sec per liter to reach different vacuum level (-kPa) | ||||||||
| bar | Nl/min | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 |
| 5.5 | 21 | 0.218 | 0.556 | 1.00 | 1.576 | 2.356 | 3.44 | 5.27 | 10.216 | – |
치수정보
| VTOM5X(n): |
| Unit: mm |

|
|
주문번호
Vacuum Pumps & Spare Parts
| Part Number | Description |
| MS18-3-1 | 2/2-way sol valve, G1/8″ inlet, DC 24V, DIN type |
| MS18-3-2 | 2/2-way sol valve, G1/8″ inlet, DC 24V, DIN type, Lamp |
| MS18-3-3 | 2/2-way sol valve, G1/8″ inlet, DC 24V, Conn. type, 30 cm lead wire & Lamp |
| MS18-2-1 | 2/2-way sol valve, G1/8″ inlet, AC 220V, DIN type |
| MS18-2-2 | 2/2-way sol valve, G1/8″ inlet, AC 220V, DIN type, Lamp |
| MS18-1-1 | 2/2-way sol valve, G1/8″ inlet, AC 110V, DIN type |
| MS18-1-2 | 2/2-way sol valve, G1/8″ inlet, AC 110V, DIN type, Lamp |
| VMS14-3-1 | 2/2-way sol valve, G1/4″ Inlet, DC 24V, DIN type |
| VMS14-3-2 | 2/2-way sol valve, G1/4″ Inlet, DC 24V, DIN type, Lamp |
| VMS14-3-3 | 2/2-way sol valve, G1/4″ Inlet, DC 24V, Conn. type, 30 cm lead wire & Lamp |
| VMS14-2-1 | 2/2-way sol valve, G1/4″ Inlet, AC 220V, DIN type |
| VMS14-2-2 | 2/2-way sol valve, G1/4″ Inlet, AC 220V, DIN type, Lamp |
| VMS14-1-1 | 2/2-way sol valve, G1/4″ Inlet, AC 110V, DIN type |
| Seal Kit | Please contact VMECA. |