VQ202P
Description
The VQ series has been equipped with a unique capability called the “Blow-Off”. The way this blow off system works is that it holds compressed air inside a chamber built in the vacuum speeder. This chamber holds the air until the compressed air is cut off, allowing the air within the chamber to come out and release the product quickly.
Build an Order #
1. Basic Model
Symbol | Description |
VQ202P | VQ pump, 2-stage cartridge, Twofold silencer |
2. Vacuum Port
Symbol | Description |
38F | G3/8 female, Vacuum port |
3. Vacuum Switch
Symbol | Description |
Blank | No vacuum switch |
S2 | Digital vacuum switch, No analog supply, M8-4-pins, NPN |
S2P | Digital vacuum switch, No analog supply, M8-4-pins, PNP |
SG2 | Digital vacuum switch, No analog supply, Grommet, NPN |
SG2P | Digital vacuum switch, No analog supply, Grommet, PNP |
SG3 | Digital vacuum switch, Analog supply, Grommet, NPN |
SG3P | Digital vacuum switch, Analog supply, Grommet, PNP |
S | LED vacuum switch, No analog supply, M8-3-pins, NPN |
SP | LED vacuum switch, No analog supply, M8-3-pins, PNP |
SG | LED vacuum switch, No analog supply, Grommet, NPN |
SGP | LED vacuum switch, No analog supply, Grommet, PNP |
4. Sealing Material
Symbol | Description |
Blank | NBR sealing material |
V | Viton sealing material |
E | EPDM sealing material |
Specifications
1. General Specifications
Max Vacuum Level | -90 kPa |
Open Vacuum Flow | 44 Nl/min |
Feed Pressure | 1.7 ~ 4 bar (Max 7 bar) |
Air Consumption | 40 Nl/min @ 4 bar |
Temperature | -20 ~ 80 ℃ |
Weight – Basic pump | 146 g |
2. Vacuum Flow
Max Vacuum | Feed Pressure | Vacuum Flow (Nl/min) at different vacuum level (-kPa) | |||||||||
-kPa | bar | 0 | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 |
90 | 3.14 | 44 | 36 | 25 | 17 | 16 | 14 | 10 | 7 | 3.5 | – |
89 | 4 | 42 | 39 | 29 | 21 | 16 | 12 | 9.5 | 7 | 2.4 | – |
65 | 2.2 | 39 | 27 | 17 | 16 | 14 | 8.4 | 2.6 | – | – | – |
49 | 1.7 | 39 | 20 | 16 | 12 | 5.3 | – | – | – | – | – |
3. Evacuation Time
Feed Pressure | Air Consumption | Evacuation time in sec per liter to reach different vacuum level (-kPa) | ||||||||
bar | Nl/min | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 |
3.14 | 34 | 0.15 | 0.39 | 0.95 | 1.03 | 1.28 | 1.32 | 2.12 | 3.54 | – |
4 | 40 | 0.15 | 0.42 | 0.56 | 0.8 | 0.99 | 1.21 | 1.46 | 3.74 | – |
2.2 | 26 | 0.2 | 0.47 | 0.7 | 0.92 | 1.24 | 1.35 | – | – | – |
1.7 | 22 | 0.33 | 0.47 | 0.89 | 1.93 | – | – | – | – | – |
Dimensions
VQ202P: |
Unit: mm |
No | Description |
1 | Compressed-Air Supply Port, G1/8″ |
2 | Vacuum Port, G3/8″ |
3 | Exhaust Port |
4 | Vacuum Switch, VP10 series |
5 | Two-Fold Silencer, VC203S |
Order Numbers
Basic Vacuum Pump & Spare Parts
Part Number | Description |
VQ202P | VQ pump, 2-stage cartridge, Holding plug |
VC202 | Mini vacuum cartridge, 2-stage |
VCP-M14 | Holding plug, VC202, Thread on exhaust port |